Vickers Type DG5V-7 Solenoid Valve | DG5V-7-2A | DG5V-7-2C | DG5V-7-6BL | Pilot Operated NG16 Valve
| Model Number | DG5V-7-6C-T-M-U-H5-30, DG5V-7-6C-T-M-U-H7-30, DG5V-7-2A-M-U-B6-50, DG5V-7-2C-M-U-B6-50 |
|---|
Product Description
Vickers DG4V & DG5V Series Heavy-Duty Solenoid Valves
Product Overview: The Vickers DG series is a worldwide benchmark for heavy-duty hydraulic systems. While the DG4V series features direct-operated designs, the DG5V-7 series consists of high-performance pilot-operated solenoid directional valves. Fully compliant with ISO 4401-07 (NG16 / CETOP 7) mounting standards, these valves are engineered for heavy industrial applications requiring massive flow control with minimal hydraulic shock. Their pilot-operated logic ensures exceptionally smooth and reliable switching even at maximum pressure and flow.
Featured models include: DG5V-7-2A-M-U-B6-50, DG5V-7-2C-M-U-B6-50, and DG5V-7-6BL-T-M-U-H7-30-P10.
Key Technical Advantages:
Superior Flow Management: As a Size 16 (NG16) valve, the DG5V-7 handles large system demands far exceeding direct-operated valves, with flow rates reaching up to 300 L/min and beyond.
Versatile Spool Configurations: Available in 2A (2-pos), 2C (3-pos closed center), and 6BL (specific offset logic) to match complex actuator sequences.
Integrated Pilot-Operated Design: Utilizes a pilot stage to actuate the main spool, significantly reducing hydraulic shock and extending the overall lifespan of the system.
Flexible Configuration Options: Supports U (ISO 4401 standard), various coil voltages (e.g., B6, H7), and manual overrides (M) for ease of maintenance.
Detailed Specifications & Parameters:
Featured Model Matrix:
DG5V-7-2A-M-U-B6-50: Size 16, 2-pos 4-way, pilot-operated, manual override, 50 design series.
DG5V-7-2C-M-U-B6-50: Size 16, 3-pos 4-way, closed-center spool for mid-position locking.
DG5V-7-6BL-T-M-U-H7-30-P10: Specific offset logic function, with type T (external drain), 30 design series.
Core Technical Specs:
Mounting Standard: ISO 4401-07 / NG16 / CETOP 7.
Max Operating Pressure: Rated up to 31.5 MPa (315 bar).
Control Voltage: Covers major DC and AC standards (B6 denotes specific DC configuration).
Design Series: Proven 30 and 50 series versions.



Company Profile
Our Advantages
Fast & Reliable Delivery
Extensive Partnerships
Strict Quality Assurance
Competitive Pricing
Reply within 24 hours!